What is the residual voltage of the surge protector? When the SPD device is selected and adapted, its various parameters will be comprehensively considered, and a comprehensive selection will be made. One of the parameters is the residual voltage of the surge protector, which refers to the voltage between its terminals when the lightning discharge current (8/20μs) flows through the surge protector against lightning. Today we will give a detailed introduction to the residual voltage of the surge protector.
The specific requirements for the performance of the surge protector against lightning are different according to the specific application of the protected electrical and electronic equipment. The only constant is that the voltage protection level is higher than the limit voltage, and the limit voltage is higher than the residual voltage. Therefore, the test and calculation of the residual voltage of the surge protector are of great significance to determine its voltage protection level.
Under different inrush currents, the residual voltage values are different. Sometimes due to the limitation of equipment and environment, it is difficult to test the residual voltage value if the required inrush current cannot be obtained.
Through many kinds of tests, it has been shown that the residual voltage of the zinc oxide varistor, an important component of the surge protector against lightning, is proportional to the magnitude of the inrush current and has a certain correlation when it is subjected to the inrush current. Therefore, the calculation method of the residual voltage of the surge protector is to estimate the residual voltage value under the corresponding high current through the lightning current impulse test, and the residual voltage value obtained under a small impulse current.
The residual voltage of the surge protector against lightning, such as cctv lightning surge protectors is an important reference value for determining the limit voltage and voltage protection level of the surge protector. It is the test data and an important parameter to determine the protection performance of the surge protector during the test. Usually, this parameter is not seen when the surge protector is selected and adapted. The parameters we can compare mainly include three-phase voltage values such as rated voltage, limit voltage, and maximum continuous operating voltage.
The lightning protection box of Shenzhen Techwin Lightning Technologies Co., Ltd surge protector factory are widely used in communication, electric power, finance, railway, transportation, petrochemical, security monitoring, meteorology and photovoltaic, wind power and new energy, and other industries. In addition to basic lightning surge shunts, we also offer industrial high-end modular lightning surge suppressors, which are digital, magnetic, remote, resettable, and adjustable. It is recommended to install household fire protection, fire shielding, and waterproofing surge, protectors. A waterproof surge protector can avoid lightning strikes. In addition to single series such as a single-pole, receptacle, circuit, port, multi-series surge circuit breakers are also on sale, and they are all more economical and less expensive than our similar products. Our powerful surge protection devices (PDF) can also be composed of fuses, alarms, flat wires, LED drivers, indicators. Learn more about Smart spd, Ethernet spd, lightning protection device, thunder surge protector. For more specific details, please feel free to contact us.
The Importance of Installing Lightning Protection DevicesOctober 25, 2021With the development of the society, urban construction continues to improve, the height of floors continues to increse. As the urban and city layout changes, it will affect the existing magnetic fie...view
Power Supply Protection Devices of Smoke and Heat Exhaust Ventilation (SHEV) SystemJune 26, 2024Smoke and heat exhaust ventilation systems (SHEV) play a critical role in enhancing building fire safety by ensuring smoke-free escape routes during a fire and providing residents with more time to es...view
Do Surge Protectors Stop Electrical Fires?May 14, 2025Surge protectors (SPDs) can effectively reduce the risk of electrical fires caused by surges when designed, installed and maintained in accordance with international standards (such as the IEC 61643 s...view
The role of ground potential counterattack protectorSeptember 28, 2021When the power distribution system is struck by lightning and when switching on or off inductive loads or large loads, it often produces high operating overvoltages, also called surge voltages. Surges...view
Understanding The Technology Behind Lightning Protection Devices For Building StructuresJanuary 10, 2024In the field of building safety, the technology encompassed within lightning protection devices for building structures serves as a strong shield against the unpredictable nature of lightning. This pa...view
Benefits of Using Lightning Protection DevicesMarch 1, 2024In today's fast-paced world, where technology reigns supreme, the importance of protecting our electronic devices from potential damage caused by lightning strikes cannot be understated. This is w...view