Shenzhen Techwin Lightning Technologies Co., Ltd has independently successfully developed a series of products: SPD surge protector, power surge protector, power surge protector, signal surge protector, signal surge protector, antenna feeder surge protector, monitoring system three-in-one One, two-in-one integrated lightning protection device, power over Ethernet lightning protection device (patented product), Gigabit network lightning protection device (patented product), lightning protection equipment, lightning protection socket and lightning detection for photovoltaic and wind power new energy industries, etc. .
The value of the voltage protection level Up is the voltage peak value of the SPD under the impact of In, and In is artificially set to evaluate the SPD's ability to withstand surge current, and it is the current peak value of 8 / 20 μs waveform flowing through the SPD. Because the volt-ampere characteristic curve of a certain SPD is fixed, as shown in the figure (the curve is non-linear, but the voltage value will increase with the increase of the current), so if the In value claimed for this certain SPD is different , then the corresponding Up value will be different, so the Up value is not a fixed value. In other words, the Up value under a certain In value cannot truly reflect the protection level of the SPD surge protector, because a point cannot be used to represent a curve.

The volt-ampere characteristic curve of SPD
In the actual long-term use environment of the SPD surge protector, the SPD is required to withstand many (such as 5000 times) lightning surges and operating overvoltage surges without damage. During product testing, it is impossible to carry out so many tests, so it is necessary to artificially select a nominal discharge current In that is much higher than the expected surge current ISPD to evaluate the performance of the surge protector SPD against multiple small shocks. tolerance. Under this In value, the corresponding measured Up1 value is not equal to the Up2 value measured under the expected surge current ISPD value (as shown in the figure), but due to the SPD test standard and lightning protection engineering design standard in this If the concept is not well connected, there is a misunderstanding of this parameter by engineering designers, thinking that the protection level Up value is a fixed value, no matter how large the lightning current is, the protection level is the Up value marked on the product by the manufacturer. A parameter similar to the withstand voltage value Uw of the device.
Shenzhen Techwin Lightning Technologies Co., Ltd Fengrun products are widely used in communication, electric power, finance, railway, transportation, petrochemical, security monitoring, meteorology and photovoltaic, wind power and new energy industries. At present, the company has passed ISO9001, CE, ROHS, CQC Golden Sun and many other domestic and international market authority certifications. So far, it has been successfully applied to China Mobile, China Unicom, Beijing Olympic Games, Shanghai World Expo, Shenzhen Universiade, Southern Xinjiang Railway, Guangzhou Baiyun Airport and many other major projects. Learn more about lightning protection box, leakage protector, spd telecom, ethernet spd,etc.
Common Signal Surge Protective Devices and Their Industry ApplicationsOctober 9, 2024What is a Signal Surge Protective DeviceA signal surge protective device is an electronic device that protects instruments, equipment, or systems on the signal line from damage caused by lightning str...view
Do surge protectors work against lightning?April 27, 2025Although surge protectors cannot directly prevent lightning strikes, they can significantly reduce the damage caused by lightning strikes to electrical equipment and circuits. As a specially designed ...view
Surge Protector: Safeguarding Your Devices from Power FluctuationsJanuary 5, 2024The Vulnerability of Electronic DevicesIn the digital age, our lives are intricately woven with electronic devices, from smartphones to laptops and everything in between. However, these devices are no...view
Lightning Protection Scheme for Drone Ground Control Station - Focus on SPD ConfigurationOctober 31, 20251.Core Principle: Zoning and Staged ProtectionThe Ground Control Station (GCS)—whether a fixed building, shelter, or vehicle—must be treated as a system requiring multi-layered protection. Adhering ...view
Surge Protector SPD Selection CriteriaMay 20, 2022The surge protector is divided into three levels according to the area that needs to be protected. The first level surge protector can be applied to the main power distribution cabinet in the building...view
What is the Difference Between a Class 1 Lightning Surge Protector and a Class 2?November 9, 2021Since the energy of lightning strikes is very huge, it is necessary to gradually discharge the energy of lightning strikes to the ground through a hierarchical discharge method. The first-level lightn...view