The internal components of the power surge protector SPD, such as gas discharge tubes, varistors, transient suppression diodes, etc., will have a certain impact on the performance when subjected to current shocks. cause performance degradation and deterioration.
Components are affected by temperature, humidity, etc., and their performance will gradually decline, and there is a life limit. According to the standard: the service life of electronic components is often between 8-12 years. If it is operated close to the specification limit for a long time, its life may be greatly reduced.
For example, in outdoor high temperature and high humidity conditions, the expected service life of the power surge protector SPD, such as the outdoor ethernet surge protector, is 3-5 years. However, if the system voltage is close to the maximum continuous working voltage of the surge protector SPD, or the power frequency overvoltage occurs frequently in the system, the service life of the surge protector SPD will be shorter.
The power surge protector SPD should be replaced regularly according to the site conditions (number of thunderstorm days, temperature and humidity, quality of power supply voltage, etc.). If there are many thunderstorm days in the south, and it is used in outdoor places with harsh temperature and humidity environments, it is recommended to replace it in 3-5 years; if there are few thunderstorm days in the north, the temperature and humidity environment is good, and the power supply quality is better, it can be replaced. Use more than 5-8 years to replace. As for the surge protector SPD with status indication, if the indication surge protector SPD fails, it needs to be replaced immediately. In addition, the surge protector SPD can use special detection equipment (disconnection detection) to judge whether it is invalid, or install an online lightning monitoring system for real-time monitoring, and evaluate it according to the environment and lightning impact conditions.
The power surge protector SPD is protected by discharging current to the ground, and it is not "one dozen, it will be broken". Unless the SPD is wrongly selected or the quality of the product itself is not good, a single lightning current shock The probability of causing damage to the surge protector SPD is extremely low. Therefore, investing in high-quality surge protection devices from a reliable SPD brand is essential.
The lightning arrester does not need special maintenance, just check regularly whether its connection is loose or not, and whether the working status indication is normal. When the fault indicator is red, it means that the components of the lightning arrester have been damaged, and the lightning protection effect has deteriorated, so it must be replaced immediately.
The power surge protector SPD is equipped with a tripping device. If the power surge protector SPD fails, it can be found directly through the indication window. The SPD tripping device of the surge protector is not to trip when it discharges the lightning current, but to prevent the fault current from continuing to flow through the SPD after the SPD has deteriorated and failed to cause the SPD fire. The fire risk of the signal surge protector SPD is small, so it is not required to set up a tripping device, and a special lightning protection device tester is often used for off-line detection. With the development of technology, the status indication function of signal surge protector SPD is becoming popular, and the status indication can also be used to judge whether it is good or bad.
Techwin distinguishes itself as a dependable and innovative surge protection supplier, providing a comprehensive range of cutting-edge solutions to protect your valuable electronic equipment. Our products are designed to provide unparalleled protection against electrical surges, ensuring the uninterrupted operation of your critical systems. We specialize in lightning protection boxes, leakage protectors, SPD (Surge Protective Device) for telecom applications, and Ethernet SPDs.
Detailed Explanation of Tiered Surge Protection for Distribution BoxesAugust 11, 2025In lightning protection, the surge protection device in distribution boxes plays a crucial role. According to the principle of graded lightning protection, and based on the likelihood of a building be...view
Lightning Protection Scheme for Drone Ground Control Station - Focus on SPD ConfigurationOctober 31, 20251.Core Principle: Zoning and Staged ProtectionThe Ground Control Station (GCS)—whether a fixed building, shelter, or vehicle—must be treated as a system requiring multi-layered protection. Adhering ...view
Understanding the Function and Installation Method of Surge Protection BoxJuly 3, 2024As computer networks become increasingly integrated into people's lives and work, heralding the advent of the digital and information era, the importance of data center rooms and lightning protect...view
The role of ground potential counterattack protectorSeptember 28, 2021When the power distribution system is struck by lightning and when switching on or off inductive loads or large loads, it often produces high operating overvoltages, also called surge voltages. Surges...view
The main measures for preventing direct lightning strikes on low-voltage overhead transmission linesSeptember 29, 2025I. Core Measure: Installation of Overhead Ground Wires (Shield Wires)This is the most effective and fundamental direct lightning protection measure, particularly suitable for lightning-proneareas or c...view
What is a Surge Protector?October 25, 20211. Surge protectorA surge protector is a small electrical device with two functions. The first function is to allow multiple components to be plugged into the same power outlet. The second function, w...view